Set the following parameters on the machine:
Parameter
Value
00200
010110000001
01020
01039 (2400)
TV Check0 (off)
Punch code1 (ISO)
I/O Channel0

To set the CNC up for drip feed:

Parameter
Value
0135 00000001
1803 00000000
Set "Tape mode" on.
Send the program from the computer, then press Cycle Start on the Fanuc.
To pause dripfeed, turn the Feedrate override to 0%.


Set ConnectCNC as follows:

Common Settings
NameFanuc 21iM
Baudrate 2400 (or to match CNC setting)
Data bits 7
Stop bits 2
Parity Even
Flow controlXon/Xoff
Xon Char.17
Xoff char.19
Portas available

Send Settings
Header String 
Trailer String 
End of Line Sequence
Recognize custom EOL  
Replace 
 
Check "%" characterChecked. This control requires a "%" at the beginning and end of your programs.
Skip empty linesuser's choice
Skip line numbersuser's choice
Skip non printable bytesuser's choice
Skip commentscheck "(...)" if required
Default folderFolder in which you store this machine's programs
Start transfer delayuser's choice

Receive Settings
Header String 
Trailer String 
End of Line Sequence
Recognize custom EOL 
Replace (checked)13,10
 
Check "%" characterChecked. This control requires a "%" at the beginning and end of your programs.
Skip empty linesuser's choice
Skip line numbersuser's choice
Skip non printable bytesuser's choice
Skip comments check "(...)" if required
Default folderFolder in which you store this machine's programs
Start transfer delayuser's choice

Cable Pin Out

Cable pinout for connecting Fanuc CNC

Sometimes file transfer will not run, even if all the settings are correct.
The following procedure may correct the problem, especially if you're running the machine via DNC:
Check to make sure your FIFO buffers disabled on the PC.
You access the settings in Control Panel -> System -> Hardware tab -> Device Manager.
Find your COM ports and double click the one you are communicating with.
Click the tab for Port Settings then Advanced. Uncheck the FIFO buffers.
Having this turned on can cause problems with RS232 transfer, especially DNC.

Once you have ConnectCNC and your CNC machines communicating, we strongly suggest you take the following precautions:
- Download some programs, the longer the better, from your CNC to the pc. Save them under a temporary filename so you don't overwrite the original files. Examine them for errors such as dropped or changed text.
Do this for the first few programs that you use.

These settings have been collected from users of our software and machine tool distributers. We have listed them to help users of ConnectCNC to communicate between their computers and CNC controls.
Since we have no control over the many variables involved, including such things as cable conditions, modifications to machines, condition of computer hardware, etc., we take no responsibility for any damage caused to programs or machines through the use of this software.


System requirements:
Any computer with Windows95(32 bit), 98, ME, 2000 XP, NT, Vista, Win7 & 8 (32 or 64 bit).
ConnectCNC requires at least one serial COM port, or USB/RS232c port converter.